Cook-temperature checks on every product, in line
TempComply checks the surface cooking temperature of every product, in-line and in real time. It combines thermal imaging with 3D profiling and intelligent masking to isolate each item from the belt and process, then checks every product against its agreed limit. Evidence for every product, not just the ones you probe.
Surface temperature of every product against its agreed limit
Cooked food products, set up per product
In line at the cook exit, linked to your line controls

A batch probe tells you about one product, not the batch
Cooking is a critical control point. Probing a sample of products tells you those products were cooked; it says nothing about the one at the cold edge of the belt or the one that came through during an oven dip. Under-cooking is a food-safety failure; over-cooking to be safe costs yield, energy and quality.
TempComply checks every product as it leaves the cooking process and records the result, so the probe checks your HACCP plan requires are backed by evidence for every product, not just a sample.
What TempComply checks
Every product, every time, against the temperature limit you set.
Surface temperature on every product
Every product’s surface temperature compared with the agreed limit, not an average.
Under-cooked products
Products below the limit flagged and rejected before packing.
Product separated from the process
3D profiling and masking isolate each item from the belt, trays and hot equipment.
Temperature across the belt
Results by lane and position show where the process runs cold.
A record for every product
Results recorded as evidence for the cooking critical control point.
How TempComply reaches a result
Every Bytronic system follows the same five stages. This is what each one means for TempComply.


Sense
Thermal imaging with 3D profiling captures every product as it leaves the cooking process.
Understand
Intelligent masking isolates each item and measures its surface temperature against the agreed limit.
Decide
Surface temperature is compared with the agreed limit for the running product.
Act
Under-temperature products are rejected; the operator sees which product and where.
Prove
Temperature by lane, position and time show cold spots in the process and if a fix worked.
Can you rely on the result?
Every inline inspection carries two conflicting operational risks: stopping good product (false rejects) or passing a critical defect (escapes). A vision platform is only viable if your technical team knows its measured error rate and the validation limits applied to each check. Three things keep both risks under control:
Surface temperature is measured, with 3D profiling and masking isolating each product from the belt and hot equipment. Each reading is compared with its agreed limit.
Configured to your line and tested in a live trial, not a demonstration. You see performance agaisnt an agreed baseline, including false rejects and under-temperature products missed.
Limits for each product do not change on the line without approval. Any change is controlled, re-tested and recorded.
The system you validated is the system that runs.
One system: hardware, software, integration and data
TempComply is delivered as a complete system, designed for your line, installed and commissioned by Bytronic engineers, and supported through its working life.
Hardware
Thermal camera with 3D profiling, mounting and washdown housing, control panel, industrial PC and HMI.
AI software
Bytronic software for product isolation (masking), surface-temperature measurement, including coldest-point detection and agreed limit checks, configured per product.
Integration
Installation, line integration and commissioning; reject logic through your PLC.
Data and evidence
A temperature record for every product, supporting HACCP and customer audits.
Cook-temperature checks in food production
For cooked products where every item must reach temperature.
Food and beverage
Cooked products checked for surface cooking temperature before chilling and packing.
Specification and deployment
Each system is designed for the customer’s line. Typical parameters:
| Measurement | Surface temperature of every product against agreed limit; coldest point located per item |
|---|---|
| Imaging | Thermal with 3D profiling |
| Product isolation | Intelligent masking separates each product from the process |
| Line speed | Full line speed, subject to application |
| Product types | Cooked food products, set up per product |
| Temperature range and accuracy | Hardware specific to the application. Typically -20°C to +1500°C with a baseline accuracy of ±2°C . |
| Integration | PLC; reject logic |
| Data | Temperature record per product |
A candid view before you invest
Best suited to
- Cooked products that must each reach a defined temperature
- Continuous ovens and fryers where temperature varies across the belt
- Lines that need 100% evidence for the cooking control point
Another solution may fit better for
- Core temperature validation, which still needs probes under your HACCP plan
- Seal faults on the finished pack: SealCheck DL
- Thermal checks outside food, such as fire risk or adhesive beads: TempCheck
- Glue on cartons and cases: HotSpot
Not sure which applies? Talk to an engineer and we’ll map your line. Something not covered here? Bring us the problem.
Cooking verification in practice
100% cooking verification on a continuous line
Batch probing could not show that every product reached temperature. Thermal imaging with 3D profiling found the coldest point on each product. Every product verified and recorded before packing.
TempComply works with
We choose on fit, not brand: our own technology where it gives the best outcome, partner technology where it is better, and combinations where one technology is not enough.
Frequently asked questions
Does TempComply measure core temperature?
No. TempComply measures surface temperature, without contact, on every product. Core-temperature validation still needs probes under your HACCP plan; TempComply adds evidence for every product alongside them.
What is thermal vision?
Thermal vision uses cameras that detect infrared radiation to measure surface temperature across a whole scene, without contact.
How do thermal imaging cameras work?
Every object emits infrared energy in proportion to its temperature. A thermal camera measures that energy for each pixel and converts it into a temperature map. Commissioning sets up the camera for each product’s surface so the readings are accurate.
How does TempComply support HACCP?
It checks every product at the cooking critical control point and records the result, giving evidence for every product alongside your probe checks.
Can it separate products from a hot belt?
Yes. 3D profiling and intelligent masking isolate each product from the belt and equipment before its temperature is assessed.
Prove it on your line before you commit capital
No off-the-shelf system fits a real production line perfectly, so we prove performance first, with a fully managed trial on your line.
Scope the problem
We map the exact failure, its cost and where it happens on your line.
Run a live trial
We design, install and run the inspection on a designated line, configured to your products.
Show the business case
You get real performance data against an agreed baseline and projected payback.
Install and support
We integrate, commission, train your team and support the system through its working life.
Recognised by industry




Check every product at the cook exit